The Wacker Neuson is a genuine OEM Quick Disconnect Coupling designed for the HSH hydronic surface heater and ground heater product families, including the E3000, E2200, E1250, E5000, E1100, HSH700, HSH650, HSH380, and Pureheat series. As a direct OEM replacement, the is produced to the exact specifications Wacker Neuson requires for proper fluid connection and sealing within these hydronic heating systems. This coupling serves a wide range of configurations across the full HSH lineup, including ground heaters, surface heaters, heat exchangers, hose handling systems, pump packs, and cross heaters. Ordering by part number ensures you receive the correct coupling for your specific machine configuration.
Key Features
- Genuine OEM Sealing Integrity — Manufactured to Wacker Neuson's exact material and dimensional tolerances, ensuring a leak-free connection in pressurized hydronic fluid circuits.
- Tool-Free Connect and Disconnect — Designed for fast, single-handed coupling and decoupling of hydronic hose lines without tools, keeping fluid transfer efficient during setup and breakdown.
- Broad HSH Family Compatibility — Fits a wide range of Wacker Neuson hydronic heating equipment including E3000, E2200, E5000, E1250, E1100, HSH380, HSH650, HSH700, HX-series heat exchangers, pump packs, hose handling systems, and Pureheat models.
- Prevents Fluid Loss During Disconnection — Quick disconnect design incorporates internal shutoff to minimize fluid spillage when separating hose circuits, protecting the glycol/water fluid system and the surrounding work area.
- Critical for System Pressure Maintenance — A worn or failed coupling can cause pressure drops, fluid leaks, or loss of heat transfer capacity across the entire hydronic loop, making timely replacement essential to sustained heating output.
A quick disconnect coupling is a push-to-connect, pull-to-release hydraulic fitting used to join and separate pressurized fluid lines without tools and without significant fluid loss. In a hydronic heating system like the Wacker Neuson HSH and E-series ground and surface heaters, these couplings connect the hose circuits that carry heated glycol solution between the boiler unit, heat exchanger, and hose network laid beneath concrete, soil blankets, or on work surfaces. When a quick disconnect coupling wears, cracks, or fails to seal, the system loses pressure and heated fluid escapes — reducing heating efficiency, wasting fluid, and potentially halting the curing or thawing operation until the fitting is replaced.
Part Details
| Part Number | 5000168214 |
|---|---|
| Old Part Number | 0168214 |
| Brand | Wacker Neuson |
| Part Type | Genuine OEM |
| Description | Quick Disconnect Coupling |
Compatibility & Fitment
| Name | Model | Machine Number |
|---|---|---|
| E3000 Hydronic Surface Heater with generator | E3000 | 5000620219, 5000620679, 5000620158, 5000620678, 5200014677, 5200004952, 5100017807, 5100017809, 5200014678, 5200014679, 5200014720, 5100017806, 5100017808, 5200014721, 5100017810, 5100017811, 5100025046, 5100055568, 5100056441, 5100017801, 5100056440, 5100025045 |
| HSH700 | HSH700G | 5000620243 |
| E2200 GROUND HEATER, W/ LIFT BAIL | E2200 | 5000620215, 5000620176, 5000620216, 5000620226, 5100017448, 5100017449 |
| E5000 GROUND HEATER, W/GAS BURNER | E5000 | 5000620898, 5000620897, 5000620899 |
| HP252 | HP252 | 5000620249 |
| Hydronic Surface Heater | HSH350 | 5000620254 |
| HX 60 Heat Exchanger, 230 V | HX60 | 5000620251 |
| DPP33 Dual Pump Pack | DPP33 | 5000620429 |
| HX200 Heat Exchanger | HX200 | 5000620430 |
| SPP4.4 Single Pump Pack | SPP4.4 | 5000620427 |
| DPP8.8 Dual Pump Pack | DPP8.8 | 5000620428 |
| HX15 Heat Exchanger, 220 V | HX15 | 5000620255 |
| HX100 Heat Exchanger | HX100 | 5000620432 |
| HHS702 Hose Handling System | HHS702 | 5000620426 |
| Pureheat Hydronic Heater, Oil Burner | Pureheat | 5000620245, 5000620246, 5000620190, 5000620220 |
| E1250S | E1250S | 5200012355, 5200012354 |
| E1100 GROUND HEATER | E1100 | 5000620172, 5000620244, 5200001676 |
| E3000 ES Hydronic Surface Heater | E3000ES | 5000620968, 5000620967 |
| Hydronic Surface Heater w/ Gen erator, 3000 ft hose | S3000 | 5000620218, 5000620182 |
| E12540B | E1250B | 5200012353, 5200007613 |
| HSH650 | HSH650 | 5000620991 |
| HSH380s | HSH 380S | 5100054643 |
| E 1250P Hydronic Heater, Premium, Diesel | E1250P | 5200012357, 5200012356 |
| HSH380S-Diesel, with Generator | HSH380S | 5200012371, 5200012370 |
| HSH380B-Diesel, without generator | HSH380B | 5200012359, 5200007614 |
| Hydronic Surface Heater, 700m hose | E700M | 5000620195 |
| Hose Handling System | HHS1101 | 5000620421 |
| HHS2202 Hose Handling System | HHS2202 | 5000620423 |
| HHS3002 Hose Handling System | HHS3002 | 5000620424 |
| HHS3004 Hose Handling System | HHS3004 | 5000620425 |
| HHS2502 Hose Handling System | HHS2502 | 5200003554 |
| Cross Heater with oil burner | CH5000 | 5000620240, 5000620242 |
| Hose Handling System | HHS1701 | 5000620422 |
Verify Before You Order
Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.
Why Buy From DHS Equipment
Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.
Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.