Wacker Neuson

Wacker Neuson 5000082946 Circuit Breaker 20A, 1 Pole

$6.96
(No reviews yet) Write a Review
SKU:
5000082946-Wacker Neuson
Adding... The item has been added

The Wacker Neuson Circuit Breaker 20A, 1 Pole is a genuine OEM electrical protection component designed for the LTW6K, LTW8K, and LTW20Z series light towers. As a direct OEM replacement, part is sourced to the original specification, ensuring it integrates correctly with the light tower's electrical panel without any guesswork. This circuit breaker is compatible across a wide range of LTW series configurations, including Standard T4, Tier 4i, Cold Weather, Custom, and V-series variants. Keeping this component in proper working order is essential to protecting the generator and lighting circuits on your tower during demanding jobsite use.

Key Features

  • Correct Trip Rating for LTW Electrical Panels — Rated at 20A, 1 Pole to match the original electrical panel specification in LTW series light towers, ensuring accurate overload and short-circuit protection.
  • Genuine OEM Part — Supplied by Wacker Neuson as an authorized OEM replacement, manufactured to the same electrical tolerances and trip characteristics as the original installed component.
  • Drop-In Panel Replacement — Designed to mount directly into the existing breaker panel position on compatible LTW models, aligning with the original terminal connections and panel cutout.
  • Broad LTW Series Coverage — Fits LTW6K, LTW8K, LTW20Z1, and LTW20Z3 light towers across Standard T4, Cold Weather, Custom, and Tier 4i configurations, as well as select G2.5A portable generators.
  • Electrical Circuit Protection — A correctly functioning circuit breaker prevents overloads and wiring damage from reaching lighting heads, control circuits, and generator components; a failed or weakened breaker can allow unsafe current levels or cause nuisance shutdowns that interrupt tower operation.
  • Critical Safety Component — Circuit breakers are a primary safeguard in any electrical distribution system; using the correct rated OEM breaker ensures the protection threshold matches the circuit design, reducing the risk of electrical faults or fire on site.

A circuit breaker is an automatic switching device that protects an electrical circuit by interrupting current flow when it detects an overload or short circuit. In a light tower, the circuit breaker safeguards the wiring and connected lighting or outlet circuits from drawing more current than the system is rated to handle. When a breaker trips repeatedly, fails to reset, or no longer holds under normal load, it signals that the component has reached the end of its service life and must be replaced to maintain safe, uninterrupted tower operation.

Part Details

Part Number5000082946
Old Part Number0082946
BrandWacker Neuson
Part TypeGenuine OEM
DescriptionCircuit Breaker 20A, 1 Pole

Compatibility & Fitment

Name Model Machine Number
LTW20Z-1, LIGHT TOWER 60Hz, ISUZU, CUSTOM, T4i LTW20Z1 5000620842, 5000620375, 5200004205, 5200004096, 5100051572, 5100051571, 5200014324, 5200014326, 5200018239, 5200023191, 5200024872, 5200014328
LTW6K Light Tower, Standard T4 LTW6K 5000620372, 5000620840, 5200004094, 5200024870
LTW8K Light Tower, Standard T4 LTW8K 5000620374, 5000620841, 5200004204, 5200004095, 5200023190, 5200024871
LTW20Z-3, LIGHT TOWER 60HZ, ISUZU TIER 4i LTW20Z3 5000620376, 5000620843, 5200003583, 5200004097, 5200014325, 5200014327, 5200023192, 5200023604, 5200014329
LTW20Z3-V S LIGHT TOWER, COLD WEATHER, T4i LTW20Z3-V S 5200018566, 5200018558, 5200018562, 5200023196, 5100015094, 5100022126
LTW20Z1-V S LIGHT TOWER, COLD WEATHER, T4i LTW20Z1-V S 5200018565, 5200018557, 5200018561, 5200024875, 5200023195, 5100015093, 5100022125
LTW6K-V S Light Tower, Cold Weather T4 LTW6K-V S 5200018563, 5200018555, 5200018559, 5200024873
LTW8K-V S Light Tower, Cold Weather T4 LTW8K-V S 5200018564, 5200018556, 5200023194, 5200018560, 5200024874, 5100015095, 5100022084
Light Tower LTW20Z3-V 5200012881, 5200012885, 5200012867, 5200022694
Light Tower LTW6K-V 5200012864, 5200012868, 5200012882
Light Tower LTW8K-V 5200012869, 5200012883, 5200012865
Light Tower LTW20Z1-V 5200012880, 5200012884, 5200012866
Portable Generator G2.5A 5000007188, 5000009256

Verify Before You Order

Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.

Why Buy From DHS Equipment

Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.

Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.