The Wacker Neuson is a genuine OEM 50 Amp Circuit Breaker designed for the G-series portable and skid-mounted mobile generator lineup. As a factory-original component, it meets the same electrical specifications as the part it replaces, ensuring correct trip characteristics and panel compatibility across a wide range of G-series models. This breaker is confirmed to fit G25, G50, G70, G85, G100, G120, G125, G150, G160, G180, G230, G240, and G320 series generators in standard, cold weather, custom, and extended run configurations. Sourcing OEM means the breaker drops into the existing panel without adaptation, keeping your generator protected and production-ready.
Key Features
- Correct Trip Rating for Generator Protection — Rated at 50 amps to match the original overcurrent protection spec, preventing nuisance trips and protecting connected loads from overload damage.
- Genuine OEM Electrical Component — Manufactured to Wacker Neuson's original resistance and interrupting-capacity specifications, so the breaker responds predictably under fault conditions — not just under normal load.
- Direct Panel Replacement — Mounts in the same breaker position as the factory-installed unit with matching terminal configuration, so installation is straightforward for qualified service technicians.
- Broad G-Series Compatibility — Fits skid-mounted, cold weather, custom, and extended run variants across the G25 through G320 generator families, covering a wide range of Wacker Neuson portable power applications.
- Overcurrent Safety for Electrical Systems — A correctly rated circuit breaker is the first line of defense against wiring damage and electrical fires; an undersized or worn breaker that fails to trip correctly puts both equipment and operators at risk.
A circuit breaker serves as the primary overcurrent protection device within the generator's electrical panel. When current draw exceeds the rated 50-amp threshold — due to a short circuit, overload, or fault condition — the breaker trips and interrupts power flow, protecting downstream wiring, connected equipment, and the generator's alternator from heat and damage. A breaker that fails to trip at the correct amperage, or that nuisance-trips below rating, compromises both safety and output reliability, making timely replacement with a correctly spec'd OEM part essential to safe generator operation.
Part Details
| Part Number | 5000153265 |
|---|---|
| Old Part Number | 0153265 |
| Brand | Wacker Neuson |
| Part Type | Genuine OEM |
| Description | 50 Amp Circuit Breaker |
Compatibility & Fitment
| Name | Model | Machine Number |
|---|---|---|
| Skid-mounted Mobile Generator, Custom | G70 | 5000620352, 5000620350, 5000620351, 5000009367, 5000009468, 5000620002, 5000620648, 5000620647, 5000620711, 5000620646, 5000009260, 5000620708, 5200001318, 5200006879, 5200003220, 5200008344, 5200008342, 5200008343, 5200008339, 5200008341, 5000008230, 5200008340, 5200003973, 5200003974, 5200003975, 5200014463, 5200004151, 5200014464, 5200014465, 5000009464, 5000009478, 5200008719 |
| Skid-mounted Mobile Generator | G50 | 5000009467, 5000009366, 5000620001, 5200001317, 5200014322, 5000009259, 5200014323, 5200006878, 5000620707, 5200001062, 5200022589, 5200001063, 5100042434, 5200001061, 5000008229, 5000620710, 5000620964, 5000620965, 5000620966, 5200001060, 5000009463, 5000009477, 5200014319, 5200014320 |
| Mobile Generator, Custom | G25 | 5000620346, 5000620344, 5000620345, 5000009466, 5000620004, 5000009368, 5000620642, 5000009258, 5000620709, 5000620640, 5200014460, 5200014462, 5000620641, 5200003991, 5000620931, 5200001316, 5200005557, 5000621005, 5000620706, 5000009462, 5000009476, 5200009370, 5200009371, 5200009373, 5200009375, 5200009376, 5200009377, 5200009372 |
| Mobile Generator | G85 | 5000009459, 5000620003, 5000009369, 5000009310, 5000008231, 5000009305, 5000009465 |
| Mobile Generator (Cold Weather ) | G120 | 5000620291, 5000620290, 5000620292, 5000620654, 5000620653, 5200001320, 5000620652, 5200006901, 5000620311, 5200003159, 5000620309, 5000620310, 5200003856, 5200003854, 5200003855, 5200008353, 5200008350, 5200008351, 5200008349, 5200008715, 5200014467, 5200014468, 5200014466 |
| Skid-mounted Mobile Generator | G160 | 5000009306, 5000620069, 5000620070 |
| Mobile Generator | G240 | 5000620300, 5000620301, 5000620663, 5200006904, 5000620302, 5200001323, 5000620662, 5000620661, 5200003162 |
| Mobile Generator | G150 | 5000620306, 5000620307, 5000620657, 5000620308, 5200006902, 5200001321, 5000620656, 5000620655, 5200003160, 5000620889, 5200007860, 5000620887, 5000620888, 5200014784 |
| Mobile Generator | G180 | 5000620303, 5200003161, 5000620660, 5000620304, 5000620305, 5200001322, 5200006903, 5000620659, 5000620658, 5000620886, 5000620884, 5200007861, 5000620885 |
| G100-GENERATOR, SKID, CUSTOM, DEERE T3 | G100 | 5000620651, 5000620650, 5200001319, 5000620649, 5200006900, 5200003158, 5000620312, 5000620313, 5000620314, 5200003859, 5200003857, 5200003858, 5200008348, 5200008346, 5200008347, 5200008345, 5200008716 |
| Mobile Generator (custom) | G125 | 5000620067, 5000620068, 5000009261, 5000008233 |
| G320 Generator, Standard T4i | G320 | 5000620275, 5200008718, 5200010219, 5200010260, 5200008717 |
| G230 Generator, Custom T4i | G230 | 5000620883, 5000620881, 5000620882, 5200007862 |
| Mobile Generator Skid Mounted | G110 | 5000008232 |
Verify Before You Order
Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.
Why Buy From DHS Equipment
Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.
Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.