The Wacker Neuson Block Terminal is a genuine OEM component designed for the G-series portable generator lineup, including G50, G70, G85, G100, G120, G150, G180, G230, G240, and G320 skid-mounted mobile generators. As a direct OEM replacement, it is manufactured to the exact electrical specifications of the original part, ensuring correct conductor sizing, insulation rating, and connection integrity. This terminal block serves a wide range of G-series configurations including standard, cold weather, extended run, and custom Tier 4 variants, making it a high-demand service part across the full generator product family. Verify your machine model and serial number against the fitment list before ordering to confirm compatibility.
Key Features
- Genuine OEM Electrical Rating — Manufactured to the original conductor capacity and insulation specifications, ensuring correct current-carrying performance within the generator's wiring circuit.
- Direct Drop-In Connection — Matches the original terminal positions and mounting footprint, allowing the block to seat and connect without modification to existing wiring harness routing.
- Broad G-Series Compatibility — Fits skid-mounted and mobile G50 through G320 generators across standard, cold weather, extended run, custom, and Hertz-configured variants, including Tier 3 and Tier 4 Final engine platforms.
- Protects Output Integrity — A correctly functioning terminal block maintains secure, low-resistance connections throughout the generator's output circuit; a loose or corroded block can cause voltage irregularities and output interruptions under load.
- Electrical Safety Compliance — As a primary junction point in the generator's electrical system, using a genuine OEM terminal block ensures the connection meets original insulation and separation requirements, reducing risk of arc faults or unintended contact.
A terminal block is the central wiring junction that organizes and secures multiple electrical conductors at a single, insulated connection point within the generator's electrical panel. It allows individual circuits — such as control wiring, output leads, and grounding conductors — to be cleanly terminated and reliably connected without the need for direct wire-to-wire splicing. When a terminal block degrades, cracks, or loses clamping force on its conductors, connections can loosen under vibration, leading to intermittent faults, voltage drops, or potentially unsafe open-circuit conditions during generator operation.
Part Details
| Part Number | 5000160091 |
|---|---|
| Old Part Number | 0160091 |
| Brand | Wacker Neuson |
| Part Type | Genuine OEM |
| Description | Block Terminal |
Compatibility & Fitment
| Name | Model | Machine Number |
|---|---|---|
| Skid-mounted Mobile Generator, Custom | G70 | 5000620352, 5000620350, 5000620351, 5000009367, 5000009468, 5000620002, 5000620648, 5000620647, 5000620711, 5000620646, 5200001318, 5200003220, 5200006879, 5200003975, 5200003973, 5200003974, 5200014464, 5200004151, 5000620708, 5200014463, 5200014465, 5200008344, 5200008342, 5200008343, 5200008339, 5200008341, 5200008719, 5200023226, 5200023227, 5200008340, 5200023228, 5200015952, 5100025262, 5100042499, 5100036306, 5100025814, 5100025838, 5100042496, 5100042497, 5100042498, 5100042500 |
| Skid-mounted Mobile Generator | G50 | 5000009467, 5000009366, 5000620001, 5200001062, 5200001063, 5200006878, 5200001317, 5200001060, 5200001061, 5200014322, 5200014319, 5200014320, 5200014323, 5000620707, 5200017829, 5200022589, 5100042434, 5200017830, 5100042430, 5100042435, 5000620710, 5100045494, 5000620964, 5000620965, 5000620966, 5100042431, 5100042433, 5100045085, 5100045493, 5100042432, 5100025812, 5100026954, 5100029210, 5100026955, 5100026956 |
| Mobile Generator | G85 | 5000009459, 5000620003, 5000009369 |
| G100-GENERATOR, SKID, CUSTOM, DEERE T3 | G100 | 5000620651, 5000620650, 5200001319, 5000620649, 5200003158, 5200006900, 5200003859, 5200003857, 5200003858, 5200008716, 5100045086, 5000620312, 5000620313, 5000620314, 5100045498, 5200008348, 5100033310, 5100045499, 5100045553, 5100045554, 5100045555, 5200008346, 5200008347, 5100033311, 5100049835, 5100049836, 5100049837, 5200008345, 5100033312, 5100036307, 5100025816, 5100026957, 5100026958, 5100026959, 5100029211 |
| G120-GENERATOR, SKID, CUSTOM, DEERE T3 | G120 | 5000620654, 5000620653, 5200001320, 5000620652, 5200006901, 5200003159, 5200003856, 5200003854, 5200003855, 5200014467, 5200014468, 5200008715, 5000620311, 5200014466, 5000620309, 5000620310, 5200008353, 5200008350, 5200008351, 5200008349, 5100025818, 5100025840 |
| G150-GENERATOR, SKID, CUSTOM, DEERE T3 | G150 | 5000620657, 5200001321, 5200006902, 5000620656, 5000620306, 5000620655, 5200003160, 5000620889, 5000620307, 5200007860, 5200023235, 5000620308, 5000620887, 5000620888, 5200014784, 5200023236, 5200010135, 5200010136, 5200010137, 5200023237, 5100045088, 5100045570, 5100045571, 5200025554, 5100049841, 5100049842, 5100049843, 5100036309, 5100026980, 5100026981, 5100026982, 5100029212, 5100025830 |
| G180-GENERATOR, SKID, CUSTOM, DEERE T3 | G180 | 5000620660, 5200001322, 5200006903, 5000620303, 5000620658, 5000620659, 5200003161, 5000620886, 5000620884, 5200007861, 5000620304, 5000620885, 5000620305, 5200010140, 5200014470, 5200010138, 5200010139, 5200014471, 5100015615, 5200014469, 5200025555, 5100045089, 5100045575, 5100045576, 5100045590, 5100045591, 5100045592, 5100049844, 5100049845, 5100025832, 5100025842 |
| G240-GENERATOR, SKID, CUSTOM, DEERE T3 | G240 | 5000620663, 5200001323, 5200006904, 5000620662, 5000620300, 5000620661, 5200003162, 5000620301, 5000620302, 5200025556, 5100025834 |
| G230 Generator, Custom T4i | G230 | 5000620883, 5000620881, 5000620882, 5200007862, 5200010141, 5200010142, 5200010143, 5100015614, 5100045190, 5100045596, 5100045597, 5100049846, 5100049847 |
| G320 Generator, Standard T4i | G320 | 5000620275, 5200008718, 5200010219, 5200010260, 5200010144, 5200010145, 5200010146, 5100045191, 5100045601, 5100045602, 5200008717, 5100018533, 5100049848, 5100049849, 5200010261 |
| G130 Generator, Standard T4i | G130 | 5200023232, 5200023233, 5200023234, 5100045087, 5100045559, 5100045560, 5100045564, 5100045565, 5100045566, 5100049838, 5100049839, 5100049840, 5100036308 |
| Mobile Generator | G95 | 5200016642 |
| G150 Generator,Hertz,T4 Final | G150 Generator,Hertz,T4 Final | 5100015616 |
| Mobile Generator | G60 | 5200015951 |
| Generator | G40 | 5200015906, 5200015907 |
Verify Before You Order
Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.
Why Buy From DHS Equipment
Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.
Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.