Wacker Neuson

Wacker Neuson 5000165146 Generator Complete

$1,046.56
(No reviews yet) Write a Review
SKU:
5000165146-Wacker Neuson
Adding... The item has been added

The Wacker Neuson Generator Complete is a genuine OEM power generation assembly designed for the LTN6, LTW6, and LTV6 series light towers, as well as E-series ground heaters including E2200 and E3000 models. Sourced directly from Wacker Neuson, this is the same unit installed at the factory, ensuring correct electrical output, mounting alignment, and connector compatibility across the full range of supported machines. It fits an extensive lineup spanning Caterpillar, Kohler, Kubota, and Lombardini engine variants, as well as 50 Hz, 60 Hz, standard, cold-weather, and custom-build configurations. When your existing generator assembly begins to underperform — or fails outright — replacing it with part number restores full electrical output capacity to your light tower or ground heater without the guesswork of cross-referencing aftermarket alternatives.

Key Features

  • Correct Output Specification — Genuine OEM construction ensures the generator delivers the precise voltage and frequency output required by your specific LTN6, LTW6, or LTV6 configuration, whether 50 Hz or 60 Hz.
  • Complete Drop-In Assembly — Supplied as a complete unit with all internal windings and housing intact, matching the original mounting footprint and electrical connection points for a straightforward swap.
  • Broad Verified Fitment — Confirmed across LTN6C, LTN6L, LTN6K, LTW6K, LTV6K, LTV6L, E2200, and E3000 model families, covering standard, cold-weather, custom Tier 4F, and racked configurations.
  • Restores Full Lighting and Heating Capacity — A failed or degraded generator assembly causes flickering output, voltage drop, or complete loss of power to light heads or heating elements; this replacement brings the system back to full operational spec.
  • Electrical System Integrity — Using the correct OEM generator assembly is critical in light tower and ground heater applications where consistent voltage output directly affects connected electrical loads and control system stability.

The generator complete assembly is the primary source of electrical power in a light tower or ground heater unit. Driven by the machine's engine, it converts mechanical energy into AC electrical output that powers the light heads, control panel, and — in ground heater applications — the heating elements and circulation systems. When the generator assembly wears or fails, the machine loses the ability to sustain consistent power output, resulting in dimming lights, tripped breakers, or a complete loss of function. Replacing the assembly with a correctly matched unit like the Wacker Neuson 5000165146 ensures that voltage, frequency, and load capacity are restored to the levels the machine's electrical system was designed to operate with.

Part Details

Part Number5000165146
Old Part Number0165146
BrandWacker Neuson
Part TypeGenuine OEM
DescriptionGenerator Complete

Compatibility & Fitment

Name Model Machine Number
LTN6C, CATERPILLAR LTN6C 5000620118, 5000620551, 5000620728, 5000620555, 5200004091, 5200022157
LTN6C-P LIGHT TOWER,60 HZ LTN6C-P 5000620298
LTN6L, KOHLER (LOMBARDINI) LTN6L 5000620117, 5000620727, 5000620550, 5000620553, 5200004090, 5200004768, 5200012438, 5200017094, 5200017095
LTN6L-P LIGHT TOWER,60 HZ LTN6L-P 5000620297
LTW6K Light Tower, Standard T4 LTW6K 5000620372, 5000620840, 5200004094, 5200024870
LTN6K Light Tower LTN6K 5000620734, 5200022156, 5200022147
E1250S E1250S 5200012355, 5200012354
LTN6L 50 Hz Non CE. Custom LTC6L 5000620559
LTN6K LIGHT TOWER, CUSTOM, Tier 4F LTN6K-LT 5000620938, 5200004092, 5200004769
LTN6K-V S, KUBOTA, 120/240V LTN6K-V S 5200018537, 5200018550, 5200018553, 5200023197
LTN6L-V LIGHT TOWER,50HZ LTN6L-V 5200002720, 5200002721
LTN6K-V LIGHT TOWER,60HZ LTN6K-V 5200002722, 5200002726
LTW6K-V S Light Tower, Cold Weather T4 LTW6K-V S 5200018563, 5200018555, 5200018559, 5200024873
E3000 Ground Heater, 3kW Gen, TC E3000 5100017807, 5100017809, 5100017806, 5100017808, 5100017810, 5100017811, 5100055568, 5100056441, 5100017801, 5100056440
LTN8K LIGHT TOWER, COLD WEATHER, Tier 4F LTN8K-LT 5200004093
Light Tower LTW6K-V 5200012864, 5200012868, 5200012882
LTN6L-V S, KOHLER (LOMBARDINI) LTN6L-V S 5200018536, 5200018539, 5200018573, 5200018552, 5200023687, 5200023688, 5200023689, 5200018576
E 1250P Hydronic Heater, Premium, Diesel E1250P 5200012357, 5200012356
LTN6LE, KOHLER (LOMBARDINI) WITH LED LIGHTS LTN6LE 5200019143
E2200 GROUND HEATER, 3kW GENERATOR E2200 5100017448, 5100017449
Light Tower LTV6K 5100039424
Light Tower LTV6L 5100039607

Verify Before You Order

Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.

Why Buy From DHS Equipment

Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.

Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.