The Wacker Neuson Generator Complete is a genuine OEM power generation assembly designed for the LTN6, LTW6, and LTV6 series light towers, as well as E-series ground heaters including E2200 and E3000 models. Sourced directly from Wacker Neuson, this is the same unit installed at the factory, ensuring correct electrical output, mounting alignment, and connector compatibility across the full range of supported machines. It fits an extensive lineup spanning Caterpillar, Kohler, Kubota, and Lombardini engine variants, as well as 50 Hz, 60 Hz, standard, cold-weather, and custom-build configurations. When your existing generator assembly begins to underperform — or fails outright — replacing it with part number restores full electrical output capacity to your light tower or ground heater without the guesswork of cross-referencing aftermarket alternatives.
Key Features
- Correct Output Specification — Genuine OEM construction ensures the generator delivers the precise voltage and frequency output required by your specific LTN6, LTW6, or LTV6 configuration, whether 50 Hz or 60 Hz.
- Complete Drop-In Assembly — Supplied as a complete unit with all internal windings and housing intact, matching the original mounting footprint and electrical connection points for a straightforward swap.
- Broad Verified Fitment — Confirmed across LTN6C, LTN6L, LTN6K, LTW6K, LTV6K, LTV6L, E2200, and E3000 model families, covering standard, cold-weather, custom Tier 4F, and racked configurations.
- Restores Full Lighting and Heating Capacity — A failed or degraded generator assembly causes flickering output, voltage drop, or complete loss of power to light heads or heating elements; this replacement brings the system back to full operational spec.
- Electrical System Integrity — Using the correct OEM generator assembly is critical in light tower and ground heater applications where consistent voltage output directly affects connected electrical loads and control system stability.
The generator complete assembly is the primary source of electrical power in a light tower or ground heater unit. Driven by the machine's engine, it converts mechanical energy into AC electrical output that powers the light heads, control panel, and — in ground heater applications — the heating elements and circulation systems. When the generator assembly wears or fails, the machine loses the ability to sustain consistent power output, resulting in dimming lights, tripped breakers, or a complete loss of function. Replacing the assembly with a correctly matched unit like the Wacker Neuson 5000165146 ensures that voltage, frequency, and load capacity are restored to the levels the machine's electrical system was designed to operate with.
Part Details
| Part Number | 5000165146 |
|---|---|
| Old Part Number | 0165146 |
| Brand | Wacker Neuson |
| Part Type | Genuine OEM |
| Description | Generator Complete |
Compatibility & Fitment
| Name | Model | Machine Number |
|---|---|---|
| LTN6C, CATERPILLAR | LTN6C | 5000620118, 5000620551, 5000620728, 5000620555, 5200004091, 5200022157 |
| LTN6C-P LIGHT TOWER,60 HZ | LTN6C-P | 5000620298 |
| LTN6L, KOHLER (LOMBARDINI) | LTN6L | 5000620117, 5000620727, 5000620550, 5000620553, 5200004090, 5200004768, 5200012438, 5200017094, 5200017095 |
| LTN6L-P LIGHT TOWER,60 HZ | LTN6L-P | 5000620297 |
| LTW6K Light Tower, Standard T4 | LTW6K | 5000620372, 5000620840, 5200004094, 5200024870 |
| LTN6K Light Tower | LTN6K | 5000620734, 5200022156, 5200022147 |
| E1250S | E1250S | 5200012355, 5200012354 |
| LTN6L 50 Hz Non CE. Custom | LTC6L | 5000620559 |
| LTN6K LIGHT TOWER, CUSTOM, Tier 4F | LTN6K-LT | 5000620938, 5200004092, 5200004769 |
| LTN6K-V S, KUBOTA, 120/240V | LTN6K-V S | 5200018537, 5200018550, 5200018553, 5200023197 |
| LTN6L-V LIGHT TOWER,50HZ | LTN6L-V | 5200002720, 5200002721 |
| LTN6K-V LIGHT TOWER,60HZ | LTN6K-V | 5200002722, 5200002726 |
| LTW6K-V S Light Tower, Cold Weather T4 | LTW6K-V S | 5200018563, 5200018555, 5200018559, 5200024873 |
| E3000 Ground Heater, 3kW Gen, TC | E3000 | 5100017807, 5100017809, 5100017806, 5100017808, 5100017810, 5100017811, 5100055568, 5100056441, 5100017801, 5100056440 |
| LTN8K LIGHT TOWER, COLD WEATHER, Tier 4F | LTN8K-LT | 5200004093 |
| Light Tower | LTW6K-V | 5200012864, 5200012868, 5200012882 |
| LTN6L-V S, KOHLER (LOMBARDINI) | LTN6L-V S | 5200018536, 5200018539, 5200018573, 5200018552, 5200023687, 5200023688, 5200023689, 5200018576 |
| E 1250P Hydronic Heater, Premium, Diesel | E1250P | 5200012357, 5200012356 |
| LTN6LE, KOHLER (LOMBARDINI) WITH LED LIGHTS | LTN6LE | 5200019143 |
| E2200 GROUND HEATER, 3kW GENERATOR | E2200 | 5100017448, 5100017449 |
| Light Tower | LTV6K | 5100039424 |
| Light Tower | LTV6L | 5100039607 |
Verify Before You Order
Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.
Why Buy From DHS Equipment
Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.
Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.