The Wacker Neuson 5000165165 Light Complete, 1000W is a genuine OEM light assembly designed for the LTN6, LTW6K, LTW8K, and LTW20Z series light towers. Sourced directly from Wacker Neuson, this assembly meets the original output and fitment specifications used in production. It is compatible across a broad range of LTN and LTW light tower configurations, including 50 Hz and 60 Hz variants, cold-weather builds, and custom-spec units. When a light head fails or degrades, swapping in a correct OEM assembly restores full illumination output to keep your worksite lit and your equipment performing as intended.
Key Features
- Genuine OEM Light Output Rating: — Rated at 1,000W to match the original luminous output spec, ensuring the tower delivers the illumination coverage it was designed for.
- Drop-In Assembly: — Ships as a complete light unit ready to mount directly onto the mast head, replacing the failed assembly without sourcing individual sub-components.
- Broad LTN and LTW Series Fitment: — Fits LTN6C, LTN6L, LTN6K, LTN8K, LTW6K, LTW8K, and LTW20Z series towers across multiple configurations including 50 Hz, 60 Hz, cold-weather, and custom-spec builds.
- Electrical Integrity: — As a genuine Wacker Neuson part, the lamp assembly is matched to the tower's ballast and wiring harness, reducing the risk of voltage mismatch or premature lamp failure.
- Worksite Safety Compliance: — A properly functioning 1,000W light assembly is critical for maintaining illuminated work areas on night operations; a failed or degraded unit compromises site visibility and safety.
The light assembly on a portable light tower is the primary illumination source, converting electrical power from the onboard generator into usable worksite lighting. A complete light unit houses the lamp, reflector, and housing components that together direct and protect the output. When the assembly burns out, cracks, or fails electrically, the tower loses usable light output entirely — halting night operations or leaving a worksite underlit. Replacing it with the correct 1,000W OEM assembly restores full performance and ensures the electrical load drawn from the generator stays within the designed operating range.
Part Details
| Part Number | 5000165165 |
|---|---|
| Old Part Number | 0165165 |
| Brand | Wacker Neuson |
| Part Type | Genuine OEM |
| Description | Light Complete, 1000W |
Compatibility & Fitment
| Name | Model | Machine Number |
|---|---|---|
| LTN6C-P LIGHT TOWER,60 HZ | LTN6C-P | 5000620298 |
| LTN6C, CATERPILLAR | LTN6C | 5000620118, 5000620551, 5000620728, 5000620555, 5200004091, 5200022157 |
| LTN6L-P LIGHT TOWER,60 HZ | LTN6L-P | 5000620297 |
| LTN6L-LIGHT TOWER,50HZ | LTN6L | 5000620121, 5000620117, 5000620550, 5000620727, 5000620552, 5000620120, 5000620119, 5000620553, 5200004090, 5200004768, 5200012438, 5200022990, 5200017095, 5200017094, 5200022155, 5100027056 |
| LTW20Z-1, LIGHT TOWER 60Hz, ISUZU, CUSTOM, T4i | LTW20Z1 | 5000620842, 5000620375, 5200004205, 5200004096, 5200014324, 5200014326, 5200018239, 5200024872, 5200023191, 5200014328 |
| LTW6K Light Tower, Standard T4 | LTW6K | 5000620372, 5000620840, 5200004094, 5200024870 |
| LTW8K Light Tower, Standard T4 | LTW8K | 5000620374, 5000620841, 5200004204, 5200004095, 5200024871, 5200023190 |
| LTW20Z-3, LIGHT TOWER 60HZ, ISUZU TIER 4i | LTW20Z3 | 5000620376, 5000620843, 5200003583, 5200004097, 5200023192, 5200014327, 5200023604, 5200014325, 5200014329 |
| LTN6K Light Tower | LTN6K | 5000620734, 5200022156, 5200022147 |
| LTN8K, KUBOTA | LTN8K | 5000620893, 5000620939 |
| LTN6L 50 Hz Non CE. Custom | LTC6L | 5000620559 |
| LTN6K LIGHT TOWER, CUSTOM, Tier 4F | LTN6K-LT | 5000620938, 5200004092, 5200004769 |
| LTN8K-V LIGHT TOWER,60HZ | LTN8K-V | 5200002727, 5200002728 |
| LTN6K-V S, KUBOTA, 120/240V | LTN6K-V S | 5200018537, 5200018550, 5200018553, 5200023197 |
| LTN6L-V LIGHT TOWER,50HZ | LTN6L-V | 5200002720, 5200002721, 5200002716, 5200002717, 5200002719, 5200002718, 5200017102, 5200019283 |
| LTW6K-V S Light Tower, Cold Weather T4 | LTW6K-V S | 5200018563, 5200018555, 5200018559, 5200024873 |
| LTN6K-V LIGHT TOWER,60HZ | LTN6K-V | 5200002722, 5200002726 |
| LTW8K-V S Light Tower, Cold Weather T4 | LTW8K-V S | 5200018564, 5200018556, 5200023194, 5200018560, 5200024874, 5100015095, 5100022084 |
| Light Tower | LTW20Z3-V S | 5200023196, 5200018562, 5200018558, 5200018566, 5100022126, 5100015094 |
| Light Tower | LTW20Z3-V | 5200012881, 5200012867, 5200022694, 5200012885 |
| LTN8K LIGHT TOWER, COLD WEATHER, Tier 4F | LTN8K-LT | 5200004093 |
| Light Tower | LTW20Z1-V S | 5200024875, 5200018557, 5200018561, 5200023195, 5200018565, 5100015093, 5100022125 |
| Light Tower | LTW6K-V | 5200012864, 5200012868, 5200012882 |
| Light Tower | LTW20Z1-V | 5200012880, 5200012866, 5200012884 |
| Light Tower | LTW8K-V | 5200012869, 5200012865, 5200012883 |
| LTN6L-V S, KOHLER (LOMBARDINI) | LTN6L-V S | 5200018536, 5200018573, 5200018539, 5200023688, 5200023687, 5200018552, 5200023689, 5200018576 |
| Mobile Generators | G60 | 5200016641, 5200015951, 5100029185 |
| G70 | G70 | 5200015952, 5100022041, 5100022040 |
| LTN8K-V S, KUBOTA, 120/240V | LTN8K-V S | 5200018538, 5200018551, 5200018554, 5200023198 |
| LTN6L 50 Hz CE- RACKED | LTN6LE | 5200019142, 5200019143, 5200019141 |
| Light cpl. | Light cpl. | 5100039531 |
| Light Tower | LTV6K | 5100039424 |
| Light Tower | LTV8K | 5100039425 |
| Light Tower | LTV6L | 5100039607 |
Verify Before You Order
Fitment is machine-number and revision-specific; always confirm your model and serial number against the fitment list.
Why Buy From DHS Equipment
Every part is verified against the manufacturer's part number before it ships, so what you order is what arrives. We carry parts from leading OEM brands and our own DHS Quality Parts line of professional aftermarket components. Need help finding the right part? Our team is available to confirm compatibility whenever you need it. Orders are processed fast to keep your jobs on track. We don't just sell parts. We keep you jobsite ready.
Questions? Contact our team at [email protected] or 866-611-9369 — DHS Equipment is here to help you maintain peak performance.