Blog

How-to: Wacker VP1340, VP1550 & VP2050 Belt Replacement

Posted by David Schatz, Owner - DHS Equipment on Apr 1st 2017

Replacing the belt on the Wacker VP1340, VP1550, and VP2050 plate compactor is a common task. We sell hundreds of belts per year, so we've added this how-to to help guide you while replacing t … read more

How-to: Wacker WP1540 & WP1550 Belt Replacement

Posted by David Schatz, Owner - DHS Equipment on Mar 31st 2017

The drive belt on the Wacker WP1540 and WP1550 should be inspected every 2 weeks or after every 50 hours of operation. Proper deflection of the drive belt is between 1/4"-3/8", halfway between the pul … read more

How-to: Wacker BPU3545 Belt Adjustment & Replacement

Posted by David Schatz, Owner - DHS Equipment on Mar 30th 2017

The Wacker BPU3545 drive belt should be inspected and/or adjusted weekly or after every 50 hours of operation. After installing a new belt on the Wacker BPU3545, check the belt tension after the … read more

How-to: Wacker BPU3545 Exciter Oil

Posted by David Schatz, Owner - DHS Equipment on Mar 30th 2017

The exciter oil on the BPU3545 must be changed after every 300 operating hours to ensure maximum protection of the exciter assembly.The bearings in the exciter assembly are splash lubricated and rotat … read more

How-to: Wacker BPU2440 & BPU2950 Control Circuit Oil

Posted by David Schatz, Owner - DHS Equipment on Mar 30th 2017

Check oil level in control handle once a week or every 25 hours.Remove plug from top of control handle. Add oil as required to maintain proper oil level. Oil level should be at “OEL” mark on outs … read more